Indiana Administrative Code (Last Updated: December 20, 2016) |
Title 675. FIRE PREVENTION AND BUILDING SAFETY COMMISSION |
Article 675IAC14. ONE AND TWO FAMILY DWELLING CODE |
Rule 675IAC14-4.3. 2005 Indiana Residential Code |
Section 675IAC14-4.3-86.5. Table R502.5(1); girder spans and header spans for exterior bearing walls
-
5. Delete Table R502.5(1) and substitute to read as follows:
TABLE R502.5(1)
GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS
(Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and regulated number of jack studs)
Girders and Headers Supporting
Size
Ground Snow Load (psf) e
30
50
70
Building width c (feet)
20
28
36
20
28
36
20
28
36
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Span
NJd
Roof and Ceiling
2-2×4
3-6
1
3-2
1
2-10
1
3-2
1
2-9
1
2-6
1
2-10
1
2-6
1
2-3
1
2-2×6
5-5
1
4-8
1
4-2
1
4-8
1
4-1
1
3-8
2
4-2
1
3-8
2
3-3
2
2-2×8
6-10
1
5-11
2
5-4
2
5-11
2
5-2
2
4-7
2
5-4
2
4-7
2
4-1
2
2-2×10
8-5
2
7-3
2
6-6
2
7-3
2
6-3
2
5-7
2
6-6
2
5-7
2
5-0
2
2-2×12
9-9
2
8-5
2
7-6
2
8-5
2
7-3
2
6-6
2
7-6
2
6-6
2
5-10
3
3-2×8
8-4
1
7-5
1
6-8
1
7-5
1
6-5
2
5-9
2
6-8
1
5-9
2
5-2
2
3-2×10
10-6
1
9-1
2
8-2
2
9-1
2
7-10
2
7-0
2
8-2
2
7-0
2
6-4
2
3-2×12
12-2
2
10-7
2
9-5
2
10-7
2
9-2
2
8-2
2
9-5
2
8-2
2
7-4
2
4-2×8
9-2
1
8-4
1
7-8
1
8-4
1
7-5
1
6-8
1
7-8
1
6-8
1
5-11
2
4-2×10
11-8
1
10-6
1
9-5
2
10-6
1
9-1
2
8-2
2
9-5
2
8-2
2
7-3
2
4-2×12
14-1
1
12-2
2
10-11
2
12-2
2
10-7
2
9-5
2
10-11
2
9-5
2
8-5
2
Roof, Ceiling, and One Center-
Bearing Floor
2-2×4
3-1
1
2-9
1
2-5
1
2-9
1
2-5
1
2-2
1
2-7
1
2-3
1
2-0
1
2-2×6
4-6
1
4-0
1
3-7
2
4-1
1
3-7
2
3-3
2
3-9
2
3-3
2
2-11
2
2-2×8
5-9
2
5-0
2
4-6
2
5-2
2
4-6
2
4-1
2
4-9
2
4-2
2
3-9
2
2-2×10
7-0
2
6-2
2
5-6
2
6-4
2
5-6
2
5-0
2
5-9
2
5-1
2
4-7
3
2-2×12
8-1
2
7-1
2
6-5
2
7-4
2
6-5
2
5-9
3
6-8
2
5-10
3
5-3
3
3-2×8
7-2
1
6-3
2
5-8
2
6-5
2
5-8
2
5-1
2
5-11
2
5-2
2
4-8
2
3-2×10
8-9
2
7-8
2
6-11
2
7-11
2
6-11
2
6-3
2
7-3
2
6-4
2
5-8
2
3-2×12
10-2
2
8-11
2
8-0
2
9-2
2
8-0
2
7-3
2
8-5
2
7-4
2
6-7
2
4-2×8
8-1
1
7-3
1
6-7
1
7-5
1
6-6
1
5-11
2
6-10
1
6-0
2
5-5
2
4-2×10
10-1
1
8-10
2
8-0
2
9-1
2
8-0
2
7-2
2
8-4
2
7-4
2
6-7
2
4-2×12
11-9
2
10-3
2
9-3
2
10-7
2
9-3
2
8-4
2
9-8
2
8-6
2
7-7
2
Roof, Ceiling, and One Clear Span Floor
2-2×4
2-8
1
2-4
1
2-1
1
2-7
1
2-3
1
2-0
1
2-5
1
2-1
1
1-10
1
2-2×6
3-11
1
3-5
2
3-0
2
3-10
2
3-4
2
3-0
2
3-6
2
3-1
2
2-9
2
2-2×8
5-0
2
4-4
2
3-10
2
4-10
2
4-2
2
3-9
2
4-6
2
3-11
2
3-6
2
2-2×10
6-1
2
5-3
2
4-8
2
5-11
2
5-1
2
4-7
3
5-6
2
4-9
2
4-3
3
2-2×12
7-1
2
6-1
3
5-5
3
6-10
2
5-11
3
5-4
3
6-4
2
5-6
3
5-0
3
3-2×8
6-3
2
5-5
2
4-10
2
6-1
2
5-3
2
4-8
2
5-7
2
4-11
2
4-5
2
3-2×10
7-7
2
6-7
2
5-11
2
7-5
2
6-5
2
5-9
2
6-10
2
6-0
2
5-4
2
3-2×12
8-10
2
7-8
2
6-10
2
8-7
2
7-5
2
6-8
2
7-11
2
6-11
2
6-3
2
4-2×8
7-2
1
6-3
2
5-7
2
7-0
1
6-1
2
5-5
2
6-6
1
5-8
2
5-1
2
4-2×10
8-9
2
7-7
2
6-10
2
8-7
2
7-5
2
6-7
2
7-11
2
6-11
2
6-2
2
4-2×12
10-2
2
8-10
2
7-11
2
9-11
2
8-7
2
7-8
2
9-2
2
8-0
2
7-2
2
Roof, Ceiling, and Two Center- Bearing Floors
2-2×4
2-7
1
2-3
1
2-0
1
2-6
1
2-2
1
1-11
1
2-4
1
2-0
1
1-9
1
2-2×6
3-9
2
3-3
2
2-11
2
3-8
2
3-2
2
2-10
2
3-5
2
3-0
2
2-8
2
2-2×8
4-9
2
4-2
2
3-9
2
4-7
2
4-0
2
3-8
2
4-4
2
3-9
2
3-5
2
2-2×10
5-9
2
5-1
2
4-7
3
5-8
2
4-11
2
4-5
3
5-3
2
4-7
3
4-2
3
2-2×12
6-8
2
5-10
3
5-3
3
6-6
2
5-9
3
5-2
3
6-1
3
5-4
3
4-10
3
3-2×8
5-11
2
5-2
2
4-8
2
5-9
2
5-1
2
4-7
2
5-5
2
4-9
2
4-3
2
3-2×10
7-3
2
6-4
2
5-8
2
7-1
2
6-2
2
5-7
2
6-7
2
5-9
2
5-3
2
3-2×12
8-5
2
7-4
2
6-7
2
8-2
2
7-2
2
6-5
3
7-8
2
6-9
2
6-1
3
4-2×8
6-10
1
6-0
2
5-5
2
6-8
1
5-10
2
5-3
2
6-3
2
5-6
2
4-11
2
4-2×10
8-4
2
7-4
2
6-7
2
8-2
2
7-2
2
6-5
2
7-7
2
6-8
2
6-0
2
4-2×12
9-8
2
8-6
2
7-8
2
9-5
2
8-3
2
7-5
2
8-10
2
7-9
2
7-0
2
Roof, Ceiling, and Two Clear Span Floors
2-2×4
2-1
1
1-8
1
1-6
2
2-0
1
1-8
1
1-5
2
2-0
1
1-8
1
1-5
2
2-2×6
3-1
2
2-8
2
2-4
2
3-0
2
2-7
2
2-3
2
2-11
2
2-7
2
2-3
2
2-2×8
3-10
2
3-4
2
3-0
3
3-10
2
3-4
2
2-11
3
3-9
2
3-3
2
2-11
3
2-2×10
4-9
2
4-1
3
3-8
3
4-8
2
4-0
3
3-7
3
4-7
3
4-0
3
3-6
3
2-2×12
5-6
3
4-9
3
4-3
3
5-5
3
4-8
3
4-2
3
5-4
3
4-7
3
4-1
4
3-2×8
4-10
2
4-2
2
3-9
2
4-9
2
4-1
2
3-8
2
4-8
2
4-1
2
3-8
2
3-2×10
5-11
2
5-1
2
4-7
3
5-10
2
5-0
2
4-6
3
5-9
2
4-11
2
4-5
3
3-2×12
6-10
2
5-11
3
5-4
3
6-9
2
5-10
3
5-3
3
6-8
2
5-9
3
5-2
3
4-2×8
5-7
2
4-10
2
4-4
2
5-6
2
4-9
2
4-3
2
5-5
2
4-8
2
4-2
2
4-2×10
6-10
2
5-11
2
5-3
2
6-9
2
5-10
2
5-2
2
6-7
2
5-9
2
5-1
2
4-2×12
7-11
2
6-10
2
6-2
3
7-9
2
6-9
2
6-0
3
7-8
2
6-8
2
5-11
3
a Spans are given in feet and inches.
b Tabulated values assume #2 grade lumber.
c Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be interpolated.
d NJ-Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is permitted to be supported by an approved framing anchor attached to the full-height wall stud and to the header.
e Use 30 psf ground snow load for cases in which ground snow load is less than 30 psf and the roof live load is equal to or less than 20 psf.
(Fire Prevention and Building Safety Commission; 675 IAC 14-4.3-86.5; filed Mar 6, 2008, 11:13 a.m.: 20080402-IR-675070483FRA; readopted filed Aug 4, 2011, 8:35 a.m.: 20110831-IR-675110254RFA)