Section 675IAC14-4.3-276. Floor slope  


Latest version.
  •    Section S4207 Floor slope is added as follows: S4207.1 Floor slopes shall be in compliance with the following:

    (1) All slopes shall be uniform.

    (2) The slope of the floor from the shallow end wall towards the deep end shall not exceed one (1) foot in seven (7) feet (1:7) to the point of the first slope change.

    (3) The point of the first slope change shall be:

    (A) defined as the point at which the floor slope exceeds one (1) foot in seven (7) feet (1:7); and

    (B) not less than six (6) feet from the shallow end wall.

    (4) The slope of the floor from the point of the first slope change to the deep end wall shall not exceed one (1) foot in three (3) feet (1:3).

    (Fire Prevention and Building Safety Commission; 675 IAC 14-4.3-276; filed Mar 25, 2011, 10:19 a.m.: 20110420-IR-675090789FRA; readopted filed Aug 4, 2011, 8:35 a.m.: 20110831-IR-675110254RFA)