Section 675IAC13-2.6-7. Chapter 6; types of construction  


Latest version.
  •    Chapter 6 is amended as follows: (a) Amend Table 601, Fire-Resistance Rating Requirements for Building Elements (Hours), by deleting all references to footnote "d" without substitution.

      (b) Amend Section 602.4.1, Columns, by adding a sentence after "manner." to read as follows: Protection in accordance with Section 704.2 is not required.

      (c) Amend Section 603.1, Allowable materials as follows:

    (1) Change the format for numbers "3-25" to be items to this section, not additional exceptions to item "2".

    (2) Amend item 18 by deleting "803.4" and inserting "803.11".

    (Fire Prevention and Building Safety Commission; 675 IAC 13-2.6-7; filed Aug 1, 2014, 11:12 a.m.: 20140827-IR-675130339FRA, eff Dec 1, 2014)