Section 675IAC13-2.6-18. Chapter 16; structural design  


Latest version.
  •    Chapter 16 is amended as follows: (a) Amend Section 1603, Construction documents, by deleting the text and inserting to read as follows: See the General Administrative Rules (675 IAC 12-6), Industrialized Building Systems (675 IAC 15), and local ordinance.

      (b) Amend Table 1604.5, Risk Category of Buildings and Other Structures, in Risk Category III under "Nature of Occupancy", in the second item, delete "occupa" and insert "occupant".

      (c) Amend Section 1604.6, In-situ load tests, by deleting the last sentence without substitution.

      (d) Amend Section 1604.8.2, Structural walls, by deleting "1.4.4" and inserting "1.4.5".

      (e) Amend Section 1606.1, General, by deleting "1602.1" and inserting "202".

      (f) Amend TABLE 1607.1, MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS AND MINIMUM CONCENTRATED LIVE LOADS item 26, Roofs as follows:

    (1) Delete the word "Where".

    (2) Delete the word "are" after "members".

    (3) Delete ", at" after "floor".

    (4) Delete "s" in the word "single" and insert "S".

    (5) Delete ": Over" after "roofs" and insert "over".

    (6) Delete the text of footnote "g" and insert to read as follows: g. Where snow loads occur that are in excess of the design conditions, the structure shall be designed to support the loads due to the increased loads caused by drift buildup or a greater snow design determined by the registered design professional or the owner if a registered design professional is not required by the General Administrative Rules (675 IAC 12-6) or the rules for Industrialized Building Systems (675 IAC 15) (see Section 1608). For occupiable roofs, see Section 1607.12.3.

    (7) Delete the text of footnote "l" and insert to read as follows: l. Areas of occupiable roofs, other than roof gardens and assembly area, shall be designed to support the loads as required for the intended occupancy or use. The registered design professional, or owner if a registered design professional is not required by 675 IAC 12 or 675 IAC 15, shall certify in writing to the code official that the design provides the required support. Unoccupied landscaped areas of roofs shall be designed in accordance with Section 1607.12.3.1.

      (g) Amend Section 1607.8.1, Handrails and guards, by deleting Exception 1 without substitution.

      (h) Amend Section 1607.8.2, Grab bars, shower seats, and dressing room bench seats, by deleting "seat systems" and inserting "seats".

      (i) Amend Section 1608.2, Ground snow loads, by deleting the text and inserting to read as follows: The ground snow loads to be used in determining the design snow loads for roofs shall be determined in accordance with ASCE 7 and Table 1608.2.

      (j) Delete Table 1608.2, Ground Snow Loads, pg, for Alaskan Location, without substitution.

      (k) Delete Figure 1608.2, Ground Snow Loads, pg, for the United States (psf), and insert to read as follows: Table 1608.2, Ground Snow Loads (pg) and Minimum Foundation Depth by County

    NO

    COUNTY

    SNOW (pg) (PSF)1

    FOUNDATION2 (inches)

    1

    Adams

    20

    36

    2

    Allen

    20

    36

    3

    Bartholomew

    20

    24

    4

    Benton

    20

    36

    5

    Blackford

    20

    30

    6

    Boone

    20

    30

    7

    Brown

    20

    24

    8

    Carroll

    20

    36

    9

    Cass

    20

    36

    10

    Clark

    20

    24

    11

    Clay

    20

    24

    12

    Clinton

    20

    30

    13

    Crawford

    20

    24

    14

    Daviess

    20

    24

    15

    Dearborn

    20

    24

    16

    Decatur

    20

    24

    17

    Dekalb

    30

    36

    18

    Delaware

    20

    30

    19

    Dubois

    20

    24

    20

    Elkhart

    30

    36

    21

    Fayette

    20

    30

    22

    Floyd

    20

    24

    23

    Fountain

    20

    24

    24

    Franklin

    20

    24

    25

    Fulton

    30

    36

    26

    Gibson

    20

    24

    27

    Grant

    20

    30

    28

    Greene

    20

    24

    29

    Hamilton

    20

    30

    30

    Hancock

    20

    30

    31

    Harrison

    20

    24

    32

    Hendricks

    20

    30

    33

    Henry

    20

    30

    34

    Howard

    20

    30

    35

    Huntington

    20

    36

    36

    Jackson

    20

    24

    37

    Jasper

    30

    36

    38

    Jay

    20

    30

    39

    Jefferson

    20

    24

    40

    Jennings

    20

    24

    41

    Johnson

    20

    30

    42

    Knox

    20

    24

    43

    Kosciusko

    30

    36

    44

    LaGrange

    30

    36

    45

    Lake

    30*

    36

    46

    LaPorte

    30*

    36

    47

    Lawrence

    20

    24

    48

    Madison

    20

    30

    49

    Marion

    20

    30

    50

    Marshall

    30

    36

    51

    Martin

    20

    24

    52

    Miami

    20

    36

    53

    Monroe

    20

    24

    54

    Montgomery

    20

    30

    55

    Morgan

    20

    30

    56

    Newton

    30

    36

    57

    Noble

    30

    36

    58

    Ohio

    20

    24

    59

    Orange

    20

    24

    60

    Owen

    20

    24

    61

    Parke

    20

    30

    62

    Perry

    20

    24

    63

    Pike

    20

    24

    64

    Porter

    30*

    36

    65

    Posey

    20

    24

    66

    Pulaski

    30

    36

    67

    Putnam

    20

    30

    68

    Randolph

    20

    30

    69

    Ripley

    20

    24

    70

    Rush

    20

    30

    71

    St. Joseph

    30*

    36

    72

    Scott

    20

    24

    73

    Shelby

    20

    30

    74

    Spencer

    20

    24

    75

    Starke

    30

    36

    76

    Steuben

    30

    36

    77

    Sullivan

    20

    24

    78

    Switzerland

    20

    24

    79

    Tippecanoe

    20

    30

    80

    Tipton

    20

    30

    81

    Union

    20

    30

    82

    Vanderburgh

    20

    24

    83

    Vermillion

    20

    30

    84

    Vigo

    20

    24

    85

    Wabash

    20

    36

    86

    Warren

    20

    30

    87

    Warrick

    20

    24

    88

    Washington

    20

    24

    89

    Wayne

    20

    30

    90

    Wells

    20

    36

    91

    White

    20

    36

    92

    Whitley

    20

    36

    1. Snow is minimum ground snow load (pg) in pounds per square foot.

    *Indicates those counties Lake, LaPorte, Porter, St. Joseph with extreme variation and shall require investigation by the design professional, or owner when a design professional is not required, to determine the actual minimum ground snow load at each site; however, the determined minimum snow load (pg) shall be at least thirty (30) pounds per square foot. Ground snow load determination for such counties shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a two percent annual probability of being exceeded (50-year mean recurrence interval).

    2. Foundation is the minimum foundation depth to bottom of footing from the top of the grade above the footing in inches.

      (l) Amend Section 1609.1.2.1, Louvers, by deleting "54" and inserting "540".

      (m) Amend Table 1609.6.2, Net Pressure Coefficients as follows:

    (1) Amend item 3 under "Flat<Slope<6:12 (27o), Positive, 100 square feet or more, under "Partially enclosed", by deleting "10.72" and inserting "0.72".

    (2) Amend item 4, by deleting "=" in the first line before "60 feet" and inserting "≤" and insert "ASCE 7" after "(Zone 4)". In the sixth line, delete "30.8-1" and insert "30.6-1".

    (3) Amend item 5, by deleting "Zone 5" in the sixth line and inserting "Zone 4" and deleting "30.8-1" and inserting "30.6-1".

      (n) Amend Section 1611.1, Design rain loads, by adding a sentence after "weather data" to read as follows: See the Indiana Plumbing Code (675 IAC 16) for other roof drainage requirements.

      (o) Amend Section 1611.3, Controlled drainage, by adding a second paragraph to read as follows: See the Indiana Plumbing Code (675 IAC 16) for other roof drainage requirements.

      (p) Amend Section 1612.1, General, by deleting "in Section 1612.3" in the first sentence and inserting "by local ordinance".

      (q) Delete Section 1612.3, Establishment of flood hazard areas, without substitution.

      (r) Amend Section 1612.3.1, Design flood elevations, by deleting "in Section 1612.3" in the first sentence and inserting "by local ordinance".

      (s) Delete the figures 1613.3.1(1) through 1613.3.1(6) without substitution.

      (t) Amend Section 1613.3.4, Design spectral response acceleration parameters, by adding an exception to read as follows: Exception: For other than H and E occupancies, the maximum values of SDS and SD1 need not exceed the values in Table 1613.3.4.

      (u) Add TABLE 1613.3.4 MAXIMUM VALUES FOR SDS AND SD1 to read as follows:

    Site Class

    SDS

    SD1

    A

    0.30

    0.12

    B

    0.38

    0.15

    C

    0.45

    0.25

    D

    0.55

    0.32

    E

    0.75

    0.50

    F

    Note 1

    Note 1

    Note 1: Site-specific geotechnical investigation and dynamic site response analyses shall be performed to determine appropriate values.

      (v) Amend Section 1613.3.5, Determination of seismic design category as follows:

    (1) Add an exception to read as follows: Exception: For other than H and E occupancies, the seismic design category need not exceed Seismic Design Category C for buildings and structures in Risk Category Groups I, II, and III for Class 1 buildings and structures.

    (2) Delete "1613.5.5(2)" and insert "1613.3.5(2)".

    (3) In the last line after "structure," insert "T".

      (w) Add a new Section 1613.5, Existing buildings, to read as follows:

    (1) Additions, alterations, modifications, or changes of occupancy shall be in accordance with this section. Existing buildings shall be analyzed to the loads required by the code in effect at the time the building was constructed.

    (2) Add a new subsection 1613.5.1 to read as follows: 1613.5.1 Additions to existing buildings. An addition that is structurally independent from an existing structure shall be designed and constructed with the seismic requirements for new structures. An addition that is not structurally independent from an existing structure shall be designed and constructed such that the entire structure conforms to the seismic-force-resistance requirements for new structures unless the following conditions are satisfied:

    1. The addition conforms with the requirements for new structures,

    2. The addition does not increase the seismic forces in any structural element of the existing structure by more than 10 percent cumulative since the original construction, unless the element has the capacity to resist the increased forces determined in accordance with generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software, and

    3. Addition does not decrease the seismic resistance of any structural element of the existing structure by more than 10 percent cumulative since the original construction, unless the element has the capacity to resist the forces determined in accordance with generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software. If the building's seismic base shear capacity has been increased since the original construction, the percent change in base shear may be calculated relative to the increased value.

      (x) Add a new subsection 1613.5.2 to read as follows: 1613.5.2 Alterations. Alterations are permitted to be made to any structure without requiring the structure to comply with Section 1613, provided the alterations conform to the requirements for a new structure. Alterations that increase the seismic force in any existing structural element by more than 10 percent cumulative since the original construction or decrease the design strength of any existing structural element to resist seismic forces by more than five percent cumulative since the original construction shall not be permitted unless the entire seismic-force-resisting system is determined to conform generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software for a new structure. If the building's seismic base shear capacity has been increased since the original construction, the percent change in base shear may be calculated relative to the increased value.

    Exception: Alterations to existing structural elements or additions of new structural elements that are not required by generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software and are initiated for the purpose of increasing the strength or stiffness of the seismic-force-resisting system of an existing structure need not be designed for forces conforming to generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software, provided that an engineering analysis is submitted indicating the following:

    1. The design strength of existing structural elements required to resist seismic forces is not reduced.

    2. The seismic force to required existing structural elements is not increased beyond their design strength.

    3. New structural elements are detailed and connected to the existing structural elements as required by Chapter 16.

    4. New or relocated nonstructural elements are detailed and connected to existing or new structural elements as required by Chapter 16.

    5. The alterations do not create a structural irregularity as defined by generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software or make an existing structural irregularity more severe.

    6. The alterations do not result in the creation of an unsafe condition.

      (y) Add a new subsection 1613.5.3 to read as follows: 1613.5.3 Change of occupancy. When a change of occupancy results in a structure being reclassified to a higher occupancy category, the structure shall conform to the seismic requirements for the higher occupancy category.

    Exceptions: 1. Specific seismic detailing requirements of this code for a new structure shall not be required to be met where it can be shown by generally accepted engineering practices such as ASCE 7, using professional structural engineering computer software that the level of performance and seismic safety is equivalent to that of a new structure. Such analysis shall consider the regularity, overstrength, redundancy, and ductility of the structure within the context of the existing and retrofit (if any) detailing provided.

    2. When a change of use results in a structure being reclassified from Risk Category I or II to Risk Category III and the structure is located in a seismic map area where SDS < 0.33, compliance with the seismic requirements of this code are not required.

    (Fire Prevention and Building Safety Commission; 675 IAC 13-2.6-18; filed Aug 1, 2014, 11:12 a.m.: 20140827-IR-675130339FRA, eff Dec 1, 2014)