Indiana Administrative Code (Last Updated: December 20, 2016) |
Title 326. AIR POLLUTION CONTROL DIVISION |
Article 326IAC6.8. PARTICULATE MATTER LIMITATIONS FOR LAKE COUNTY |
Rule 326IAC6.8-2. Lake County: PM10 Emission Requirements |
Section 326IAC6.8-2-35. Conopco, Inc. d/b/a Unilever HPC USA
-
(a) Conopco, Inc. d/b/a Unilever HPC USA in Lake County, source identification number 00229, shall meet the following emission limits:
Emission Limits
Source
Units
lbs/hr
Stack serving boiler house, building number 8, Babcock-Wilcox boiler number 4
0.116 lbs/MMBtu
18.88
Facility milling and pelletizer detergent bar soap dust collection system (DC-1), building number 15
0.020 gr/dscf
1.03
Powder dye mixing system (DC-4), building number 15
0.020 gr/dscf
0.130
Schenible wet scrubber and demister collector system, building number 15
0.030 gr/dscf
1.030
Each stack serving soap noodle bins numbers 1, 2, and 3 dust collection system (DC-5, DC-6, and DC-7)
0.020 gr/dscf
0.210
Chip Mixer No. 1 and Chip Mixer No. 2
0.020 gr/dscf
0.720
Zinc Oxide catalyst weigh station and 3 chill rolls
0.020 gr/dscf
0.800
Three chill rolls apron conveyors (DC-2), building number 15 and screw conveyors
0.020 gr/dscf
1.090
3 vacuum system soap dryers dust collection system, building number 14
0.020 gr/dscf
0.120
5 noodle bins, 2 rework systems, and 1 scrap soap kettle dust collection system, building number 3
0.020 gr/dscf
0.860
Dust collector system for soap rework grinding process, building number 14
0.020 gr/dscf
0.250
Stack serving tallow finishing lines numbers 8, 9, 10, 11, 12, and 13 dust collection system (DC), building number 14
0.020 gr/dscf
1.540
American hydrotherm boiler 2, stack 1A, building number 15A
0.150 lbs/MMBtu
1.830
D. R. Technology wet scrubber and demister collection system, stack 2A, building number 15A
0.030 gr/dscf
1.030
Flex Kleen dust collection system DC-1053, stack 3A, building number 15A
0.020 gr/dscf
0.940
Flex Kleen dust collection system DC-1054, stack 4A, building number 15A
0.020 gr/dscf
0.940
Flex Kleen dust collection system DC-1055, stack 5A, building number 15A
0.020 gr/dscf
0.940
Flex Kleen dust collection system DC-1056, stack 6A, building number 15A
0.020 gr/dscf
0.940
Flex Kleen dust collection system DC-1052, stack 7A, building number 15A
0.020 gr/dscf
2.130
Flex Kleen dust collection system DC-1051, stack 8A, building number 15A
0.020 gr/dscf
2.130
(b) The American hydrotherm boiler number 1 shall fire natural gas only. (Air Pollution Control Division; 326 IAC 6.8-2-35; filed Aug 10, 2005, 1:00 p.m.: 28 IR 3521; filed Jan 23, 2008, 1:44 p.m.: 20080220-IR-326040279FRA)