Section 326IAC6.8-2-35. Conopco, Inc. d/b/a Unilever HPC USA  


Latest version.
  •    (a) Conopco, Inc. d/b/a Unilever HPC USA in Lake County, source identification number 00229, shall meet the following emission limits:

     

    Emission Limits

    Source

    Units

    lbs/hr

    Stack serving boiler house, building number 8, Babcock-Wilcox boiler number 4

    0.116 lbs/MMBtu

    18.88

    Facility milling and pelletizer detergent bar soap dust collection system (DC-1), building number 15

    0.020 gr/dscf

    1.03

    Powder dye mixing system (DC-4), building number 15

    0.020 gr/dscf

    0.130

    Schenible wet scrubber and demister collector system, building number 15

    0.030 gr/dscf

    1.030

    Each stack serving soap noodle bins numbers 1, 2, and 3 dust collection system (DC-5, DC-6, and DC-7)

    0.020 gr/dscf

    0.210

    Chip Mixer No. 1 and Chip Mixer No. 2

    0.020 gr/dscf

    0.720

    Zinc Oxide catalyst weigh station and 3 chill rolls

    0.020 gr/dscf

    0.800

    Three chill rolls apron conveyors (DC-2), building number 15 and screw conveyors

    0.020 gr/dscf

    1.090

    3 vacuum system soap dryers dust collection system, building number 14

    0.020 gr/dscf

    0.120

    5 noodle bins, 2 rework systems, and 1 scrap soap kettle dust collection system, building number 3

    0.020 gr/dscf

    0.860

    Dust collector system for soap rework grinding process, building number 14

    0.020 gr/dscf

    0.250

    Stack serving tallow finishing lines numbers 8, 9, 10, 11, 12, and 13 dust collection system (DC), building number 14

    0.020 gr/dscf

    1.540

    American hydrotherm boiler 2, stack 1A, building number 15A

    0.150 lbs/MMBtu

    1.830

    D. R. Technology wet scrubber and demister collection system, stack 2A, building number 15A

    0.030 gr/dscf

    1.030

    Flex Kleen dust collection system DC-1053, stack 3A, building number 15A

    0.020 gr/dscf

    0.940

    Flex Kleen dust collection system DC-1054, stack 4A, building number 15A

    0.020 gr/dscf

    0.940

    Flex Kleen dust collection system DC-1055, stack 5A, building number 15A

    0.020 gr/dscf

    0.940

    Flex Kleen dust collection system DC-1056, stack 6A, building number 15A

    0.020 gr/dscf

    0.940

    Flex Kleen dust collection system DC-1052, stack 7A, building number 15A

    0.020 gr/dscf

    2.130

    Flex Kleen dust collection system DC-1051, stack 8A, building number 15A

    0.020 gr/dscf

    2.130

      (b) The American hydrotherm boiler number 1 shall fire natural gas only. (Air Pollution Control Division; 326 IAC 6.8-2-35; filed Aug 10, 2005, 1:00 p.m.: 28 IR 3521; filed Jan 23, 2008, 1:44 p.m.: 20080220-IR-326040279FRA)