Section 326IAC6.8-2-6. BP Products North America, Inc.-Whiting Refinery  


Latest version.
  •    (a) BP Products North America, Inc.-Whiting Refinery in Lake County, source identification number 00453, shall meet the following emission limits:

     

    Emission Limits

    Source

    lbs/MMBtu

    lbs/hr

    CRU, F-101 feed preheater

    0.0075

    0.536

    Stack serving number 1 CRU, F-102A heater

    0.0075

    0.447

    Stack serving number 1 power station, boiler numbers 5, 6, and 7

    0.0075

    5.924

    Stack serving number 11 pipe still furnaces H-101, H-102, H-103, H-104, coke preheaters

    0.0075

    1.49

    Number 11 pipe still, H-1X heater

    0.0075

    1.863

    Number 11 pipe still, H-2 vacuum heater

    0.0075

    0.335

    Number 11 pipe still, H-200 crude charge

    0.0075

    1.859

    Number 11 pipe still, H-3 vacuum heater

    0.0075

    0.410

    Number 11 pipe still, H-300 furnace

    0.0075

    1.341

    Stack serving number 12 pipe still, H-1AS, H-1AN, and H-1B preheaters and H-2 vacuum heater

    0.0075

    4.918

    Each stack serving number 12 pipe still H-1CN crude preheater

    0.0075

    0.894

    Number 12 pipe still, H-1CX crude preheater

    0.0075

    3.055

    Number 2 isomerization, H-1 feed heater furnace

    0.0075

    1.416

    Each stack serving number 3 power station, boiler numbers 1, 2, 3, 4, and 6

    0.0075

    4.28

    Number 3 ultraformer, F-7 furnace

    0.0075

    0.171

    Number 3 ultraformer, H-1 feed heater furnace

    0.0075

    1.788

    Number 3 ultraformer, H-2 feed heater furnace

    0.0075

    1.378

    Stack serving number 4 ultraformer, F-1 ultrafiner furnace F-8A and F-8B reboilers

    0.0075

    2.936

    Number 4 ultraformer, F-2 preheater furnace

    0.0075

    2.131

    Number 4 ultraformer, F-3 number 1 reheat furnace

    0.0075

    1.803

    Stack serving number 4 ultraformer, F-4 number 2 reheat furnace, F-5 number 3 reheat furnace, and F-6 number 4 reheat furnace

    0.0075

    2.124

    Number 4 ultraformer, F-7 furnace

    0.0075

    0.387

    Aromatics recovery unit, F-200A furnace

    0.0075

    1.859

    Aromatics recovery unit, F-200B furnace

    0.0075

    1.859

    Blending oil desulphurization, F-401 furnace

    0.0075

    0.261

    Each stack serving the cat feed hydrotreating unit F-801 A/B and F-801C

    0.0075

    0.943

    Asphalt F-1 heater

    0.0075

    0.089

    Asphalt F-2 Steiglitz Park residual heater

    0.0075

    0.209

    Sulfur recovery unit incinerator

    0.0075

    0.285

    Beavon Stretford tail gas unit (B/S TGU)

    0.0075

    0.182

    DDU WB-301, DDU WB-302

    0.0075

    1.106

    Hydrogen unit B-501

    0.0075

    2.729

      (b) The F-100 marine docks distillate heater shall have the following emission limits:

     

    Emission Limits

    Source

    lbs/MMBtu

    lbs/hr

     

    0.0075

    0.052

      (c) BP shall comply with the following emission limits:

     

    Emission Limits

    Source

    Units

    lbs/hr

    Wastewater sludge fluid bed incinerator

    0.173 lbs/ton based on 79,000 lbs/hr fluidizing air flow

    6.84

    FCU 500

    1.220 lbs/1,000 lbs coke burned

    73.20

    FCU 600

    1.10 lbs/1,000 lbs coke burned

    55.00

      (d) Emission limits in subsections (a) and (b) apply to the sum of the filterable (front half) and condensible (back half) particulate matter. The total quantity of particulate matter emissions shall be determined in accordance with 40 CFR 51, Appendix M, Method 201A* for determining filterable matter and 40 CFR 51, Appendix M, Method 202* for determining condensibles. However, if a demonstration is made to the commissioner that excessive temperatures preclude the use of 40 CFR 51, Appendix M, Method 201A*, then the commissioner may allow the use of 40 CFR 60, Appendix A, Method 5* for determining filterable matter emissions, to be used in conjunction with 40 CFR 51, Appendix M, Method 202* for determining condensibles. Alternatives to these methods may be used, but only if they are approved in writing by U.S. EPA prior to the test.

      *These documents are incorporated by reference and are available from the Government Printing Office, 732 North Capitol Avenue NW, Washington, D.C. 20401 or are available for review and copying at the Indiana Department of Environmental Management, Office of Air Quality, Indiana Government Center-North, Tenth Floor, 100 North Senate Avenue, Indianapolis, Indiana 46204. (Air Pollution Control Division; 326 IAC 6.8-2-6; filed Aug 10, 2005, 1:00 p.m.: 28 IR 3508; filed Jan 23, 2008, 1:44 p.m.: 20080220-IR-326040279FRA; errata filed Feb 29, 2008, 8:54 a.m.: 20080312-IR-326040279ACA)