Section 312IAC5-14-17. Fire extinguishers  


Latest version.
  •    (a) A boat must be equipped with at least the minimum number of portable fire extinguishers located as follows:

    Boat Length

    No fixed systems

    With approved fixed system

    Less than 26 feet

    1 B-I

    0

    26 feet to less than 40 feet

    2 B-I or 1 B-II

    1 B-I

    40 feet to less than 65 feet

    3 B-I or 1 B-II and 1 B-I

    2 B-I or 1 B-II

    65 feet to less than 90 feet

    4 B-I or 2 B-II

    3 B-I or 2 B-II

    90 feet to less than 125 feet

    5 B-I or 3 B-II and 1 B-I

    4 B-1 or 3 B-II

    Over 125 feet

    6 B-I or 4 B-II and 1 B-I

    5 B-I or 4 B-II

      (b) A fire extinguisher must have the U.S. Coast Guard approval 162.028 or have an Underwriters Laboratory Marine listing.

      (c) A portable fire extinguisher without a gauge must be inspected at least every six (6) months and must have an inspection card attached.

      (d) A pressure-filled fire extinguisher must be hydrostatically pressure tested at least every five (5) years.

      (e) The maintenance required under subsections (c) and (d) must be performed by a qualified firefighting equipment repair service. (Natural Resources Commission; 312 IAC 5-14-17; filed Mar 23, 2001, 2:50 p.m.: 24 IR 2394, eff Jan 1, 2002; filed Jan 5, 2005, 11:05 a.m.: 28 IR 1465; readopted filed May 29, 2008, 1:53 p.m.: 20080625-IR-312080057RFA; errata filed Jun 2, 2009, 10:29 a.m.: 20090624-IR-312090386ACA; readopted filed Jul 17, 2014, 3:46 p.m.: 20140813-IR-312140067RFA)