Section 312IAC13-4-3. Pitless units and pitless adapters  


Latest version.
  •    (a) A pitless unit shall:

    (1) extend the upper end of the well casing at least one (1) foot above the ground level; and

    (2) be affixed to the well casing in a manner that is watertight by:

    (A) threading;

    (B) welding (including gluing); or

    (C) a mechanical connection.

      (b) The cap, cover, or seal of the pitless unit shall:

    (1) be self-draining and overlap the top of the casing extension with a downward flange;

    (2) fit securely on the well casing; and

    (3) be tamper resistant.

      (c) A pitless unit shall be installed under 312 IAC 13-3-2(a)(3).

      (d) A pitless adapter shall be constructed and installed to:

    (1) prevent the entrance of contaminants through openings in the well casing to which the adapter is attached; and

    (2) provide consistency with the Water Systems Council Listing of Products for PAS-97(04).

    (Natural Resources Commission; 312 IAC 13-4-3; filed Nov 22, 1999, 3:34 p.m.: 23 IR 767; readopted filed Aug 4, 2005, 6:00 p.m.: 28 IR 3661; readopted filed May 20, 2011, 3:28 p.m.: 20110615-IR-312110002RFA; filed Dec 20, 2011, 1:55 p.m.: 20120118-IR-312110332FRA)